Model: VR30, VR45,VR90, VR132
Vacuum Recovery System
- Higher productivitycompared with normal cleaning method;
- Failure is reduced since no mechanical movingon abrasive recovery line;
- Surface after treated can timely access to painting process;
- Easy to do maintenance and moving since no need to move vacuum recovery machine.
The Function of The Vacuum Sand Suction Machine
The primary function of the vacuum sand suction machine is to recover abrasive materials accumulated in ship holds, oil tanks, or dry surfaces during sandblasting processes, as well as to clean abrasive materials from ship hull sections and complex components. The design of the vacuum sand suction machine is based on a pneumatic conveying system, which utilises high-speed airflow to transport abrasive materials through wear-resistant suction tubes from the work area into a storage bin for convenient recovery.

- Technical Data Sheet
- Technical Data Sheet
- Technical Data Sheet
- Technical Data Sheet
| MODEL | VR30 | |
| Power supply | 3 phase, 380~440V, 50HZ/60HZ | |
| Process air volume | 1900 CMH | |
| Vacuum pressure | -380mmHg | |
| Rotation speed | 1239rpm | |
| Electric motor | 30kw IP55 class F | |
| Dust filtration | Cyclone and Cartridge Dust Collector Continuous Pulse-jet Valve | |
| Over Vacuum protection | Vacuum Relief Valve | |
| Protection | Wrong phase, overload, dust level | |
| Filter Cleaning | Pulse Air Jet | |
| Filter efficiency | 99.50% | |
| Noise Level | 85dB@5m radius scale A | |
| Start-stop Method | Star-Delta | |
| Control Panel | IP55 overload protection | |
| Display Gauges | Running Amperes,Vacuum | |
| Machine Structure | Open structure, compact | |
| Air cleaning | Oil/water separator @ 6 to 10 bar | |
| Air consumption | 250l/min at max 1bar | |
| Optional Accessories | Machine to Silo Hose-WGP | 4” *10m |
| Suction Hose-WGP (Silo to manifold) | 3”*20m | |
| Vacuum Hose-GL | 2”*20m*2 | |
| Air Manifold | 2 outlets | |
| Recommended Silo | 3.5T | |
| Weight | Approx 2.6T | |
| Machine dimension 0 refers without eyebolt measurement | L2.2*W1.8*H1.97M (L2.2*W1.8*H1.87m) | |
| Silo dimension | L1.72×W1.45×H2.4m | |
| Silo weight | ~1.0T | |
| Recovery rate | Up to 3.5tons/hr,30m vertical(suction),15m horizontal (machine to silo) | |
| MODEL | VR45 | |
| Power supply | 3 phase, 380~440V, 50HZ/60HZ | |
| Process air volume | 2640CMH | |
| Vacuum pressure | -430mmHg | |
| Rotation speed | 1033rpm | |
| Electric motor | 45kw IP55 class F | |
| Dust filtration | Cyclone and Cartridge Dust Collector Continuous Pulse-jet Valve | |
| Over Vacuum protection | Vacuum Relief Valve | |
| Protection | Wrong phase, overload, dust level | |
| Filter Cleaning | Pulse Air Jet | |
| Filter efficiency | 99.50% | |
| Noise Level | 85dB@5m radius scale A | |
| Start-stop Method | Star-Delta | |
| Control Panel | IP55 overload protection | |
| Display Gauges | Running Amperes,Vacuum | |
| Machine Structure | Open structure, compact | |
| Air cleaning | Oil/water separator @ 6 to 10 bar | |
| Air consumption | 750l/min at max 10bar | |
| Optional Accessories | Machine to Silo Hose-WGP | 5’’ *10m |
| Suction Hose-WGP (Silo to manifold) | 4” *20m | |
| Vacuum Hose-GL | 2-1/2’’ *20m*2 | |
| Air Manifold | 2 outlets | |
| Recommended Silo | 5T | |
| Weight | Approx 3.3T | |
| Machine dimension 0 refers without eyebolt measurement | L2.8*W2.12*H2.0M (L2.6*W2.12*H2.0m) | |
| Silo dimension | L1.9×W1.68×H2.7m | |
| Silo weight | ~1.3T | |
| Recovery rate | Up to 5tons/hr,30m vertical(suction),15m horizontal (machine to silo) | |
| MODEL | VR90 | |
| Power supply | 3 phase, 380~440V, 50HZ/60HZ | |
| Process air volume | 3600 CMH | |
| Vacuum pressure | -450mmHg | |
| Rotation speed | 1318rpm | |
| Electric motor | 90kw IP55 class F | |
| Dust filtration | Cyclone and Cartridge Dust Collector Continuous Pulse-jet Valve | |
| Over Vacuum protection | Vacuum Relief Valve | |
| Protection | Wrong phase, overload, dust level | |
| Filter Cleaning | Pulse Air Jet | |
| Filter efficiency | 99.50% | |
| Noise Level | 85dB@5m radius scale A | |
| Start-stop Method | Star-Delta | |
| Control Panel | IP55 overload protection | |
| Display Gauges | Running Amperes,Vacuum | |
| Machine Structure | Open structure, compact | |
| Air cleaning | Oil/water separator @ 6 to 10 bar | |
| Air consumption | 750l/min at max 10bar | |
| Optional Accessories | Machine to Silo Hose-WGP | 6’’ *10m |
| Suction Hose-WGP (Silo to manifold) | 5” *20m | |
| Vacuum Hose-GL | 2’’ *20m*4 | |
| Air Manifold | 4 outlets | |
| Recommended Silo | 8T | |
| Weight | Approx 4.2T | |
| Machine dimension 0 refers without eyebolt measurement | L3.65*W2.25*H2.5M (L3.45*W2.25*H2.5m) | |
| Silo dimension | L2.08×W1.86×H2.72m | |
| Silo weight | ~1.5T | |
| Recovery rate | Up to 10tons/hr,30m vertical(suction),15m horizontal (machine to silo) | |
| MODEL | VR132 | |
| Air flow rate | 5800 m³/h | |
| Vacuum pressure | -450mmHg | |
| Rotation speed | 1120 rpm | |
| Rotation speed | 250 | |
| Electric motor | 132 kW IP55 F-class insulation | |
| Power supply | 3 phase, 380~451V, 50HZ | |
| Transmission method | V-belt drive | |
| Dust filtration | Cyclone and Cartridge Dust Collector Continuous Pulse-jet Valve | |
| Over Vacuum protection | Vacuum Relief Valve | |
| Protection | Wrong phase, overload, dust level | |
| Filter Cleaning | Pulse Air Jet | |
| Filter efficiency | 99.50% | |
| Air cleaning | Oil mist separator/pressure regulator | |
| Noise Level | Below 85 dB | |
| Machine Structure | Frame structure (optional upper cover plate) | |
| Start-stop Method | Star-Delta | |
| Control Panel | IP55 overload protection | |
| Display Gauges | Running Amperes,Vacuum | |
| Air consumption | 750 l/min at 4~6bar | |
| Optional Accessories | Machine to Silo Hose-WGP | 8” *10m |
| Suction Hose-WGP (Silo to manifold) | 6”*20m+5”*10m | |
| Vacuum Hose-GL | 2-1/2”*20m*6 | |
| Air Manifold | 6 inputs, 1 output
| |
| Weight | ~5.5T | |
| Machine dimension 0 refers without eyebolt | L3.55×W2.4×H2.7m | |
| Sand pot (optional) | Capacity 3.8 m3 | |
| Silo dimension | L2.6*W1.986*H3.45m | |
| Silo weight | ~1.5T | |
| Recovery rate | 8–12 t/h horizontal distance 15 m and vertical distance 30 m | |