The RoltecG/Y4-73 boiler centrifugal blower is a high-efficiency ventilation equipment specially developed by Shandong Roltec Ventilation Equipment Co., Ltd. for industrial boiler systems. Integrating advanced centrifugal ventilation technology with the operation demands of industrial boilers, it is divided into two major series: G4-73 (forced draft fan) and Y4-73 (induced draft fan). Featuring core advantages such as stable performance, high efficiency and long service life, it is widely applicable to the air supply and exhaust scenarios of various industrial boilers. As one of the core supporting equipment for the safe and efficient operation of boiler systems in industries including thermal power generation, chemical engineering and mining, it leverages Roltec’s years of experience in fan R&D and manufacturing to provide users with reliable ventilation solutions, helping improve production efficiency and optimize energy consumption.

4-73 low pressure centrifugal fan

Core Product Positioning and Applicable Scenarios

The Roltec G/Y4-73 series boiler centrifugal blowers are corely positioned as “specialized forced draft and induced draft equipment for boiler systems”, accurately meeting the ventilation and induced draft demands of boilers in various specifications. The two sub-series feature clear functional division and strong compatibility:

G4-73 Series: Primarily applied to boiler forced ventilation and general ventilation scenarios, capable of conveying normal-temperature air (maximum temperature not exceeding 80°C). It is also widely used for mine ventilation. The conveyed medium shall be non-corrosive, non-self-igniting and non-viscous gas, with the content of dust and hard particles no more than 150mg/m³. Suitable for various small and medium-sized boilers and mine ventilation systems, it supplies sufficient fresh air for combustion and ensures complete combustion efficiency.

Y4-73 Series: Dedicated to boiler induced draft applications and specially designed for conveying flue gas generated by boiler combustion. It can withstand a medium temperature up to 250°C, matching the induced draft systems of steam boilers below 670t/h in thermal power plants, and is also applicable to flue gas emission of large industrial boilers. A dust removal device with a dust collection efficiency of no less than 85% must be installed in front of the induced draft fan. It effectively discharges combustion waste gas, maintains the negative pressure balance inside the boiler, and guarantees stable boiler operation.

The overall application scope covers various coal-fired steam boilers with a capacity ranging from 0.5 to 670t/h. Meanwhile, customized adaptation solutions are available to meet the demands of special scenarios such as mine ventilation and chemical production. It satisfies ventilation needs across multiple industries including thermal power generation, mining, chemical engineering and building materials, combining excellent universality and targeted performance.

Core Structure and Product Advantages

The product adopts a mature centrifugal structure design, consisting of an impeller, casing, air inlet, regulating damper and transmission components. All parts are precisely manufactured and operate efficiently in coordination, highlighting the quality advantages of Roltec fans. Its specific features are as follows:

(I) High Efficiency and Energy Saving with Controllable Operating Costs

The impeller adopts a backward-curved wing-shaped obliquely cut blade design, optimized through precise computational fluid dynamics simulation. It is welded with an arc-shaped conical front plate and a flat rear plate. The G4-73 and Y4-73 series of the same model feature a unified impeller structure, cutting the cost of spare parts inventory. Meanwhile, airflow resistance is greatly reduced and aerodynamic efficiency is improved. With stable air volume and wind pressure, the motor energy consumption is effectively lowered. Compared with traditional fans, it delivers remarkable energy-saving effects and can significantly reduce enterprises’ long-term power consumption costs. Equipped with an axial damper with an adjustment range from 0° (fully open) to 90° (fully closed), it can accurately adjust air volume according to boiler load to avoid energy waste and meet the operation requirements of various working conditions.

 (II) Sturdy and Durable with a Long Service Life

Strict standards are applied to the selection of core components. The impellers and blades feature a wear-resistant design, which effectively resists abrasion caused by dust in the medium and extends the service life of impellers. The main shaft is made of high-strength alloy steel, boasting high rigidity, excellent fatigue resistance and low deformation tendency, ensuring stable high-speed operation. The casing adopts a volute structure welded from ordinary steel plates, available in three structural types based on different machine sizes: integral type, two-split type and three-split type (integral for No.8~12, two-split for No.14~16, and three-split for No.18~28). Among them, the volute plates of the Y4-73 series induced draft fans are appropriately thickened to enhance wear resistance, making them suitable for flue gas conveying scenarios. Equipped with a forced oil supply lubrication system, paired with high-quality cast iron bearing housings and double-row self-aligning bearings, the unit adopts oil lubrication and transmits shaft power through couplings. Its design delivers reliable safety and fatigue resistance, significantly reducing component wear and maintenance frequency, ensuring long-term continuous and stable equipment operation with a service life far exceeding the industry average.

(III) Stable Transmission and Flexible Installation AdaptabilityIt

adopts D-type transmission, covering machine sizes from No.8 to 29.5. With high transmission efficiency, smooth operation and low vibration, it effectively reduces noise pollution during equipment operation and creates a more comfortable production environment. It supports two installation forms: left rotation and right rotation, which can be flexibly adjusted according to on-site installation space and pipeline layout to meet the installation needs of various industrial sites, lowering installation difficulty and construction costs. The air inlet adopts a convergent and streamlined integrated structure, fixed to the fan inlet side with bolts, enabling smooth air inflow and further improving operational stability and efficiency.

 (IV) High Safety and Reliability with Convenient Operation and Maintenance

The transmission part of the Y4-73 series induced draft fan is equipped with a water cooling device, which efficiently lowers the temperature of transmission components, adapts to high-temperature flue gas conveying conditions, prevents component damage caused by high temperature, and improves overall equipment operational safety. The overall equipment structure is rationally designed for easy disassembly and maintenance. Key components are simple to detach and replace, and daily maintenance requires no complex tools, greatly reducing the workload of operation and maintenance personnel as well as equipment downtime. Every unit undergoes strict static and dynamic balance calibration and overall performance testing before delivery, ensuring full compliance with industry standards and usage requirements. It prevents production delays caused by equipment failures, fully guarantees the safe and stable operation of boiler systems, and minimizes potential safety hazards.

GY4-73 Series Boiler Centrifugal Fans

Core Technical Parameters

Roltec G/Y4-73 Boiler Centrifugal Blower covers a variety of model numbers and speed specifications, enabling flexible selection based on users’ actual needs. The core technical parameters are as follows :

NOMachine Number RangeRotational speed(r/min)Flow Range(m³/h)Total Pressure Range(Pa)Motor Power(kW)
G4-73(ventilator)No.8~29.5730~145016156~5730003695~65417.5~1600
Y4-73(Induced Draft Fan)No.8~29.5580~145015229~5730002.77~35987.5~1250

Note: The above are conventional parameter ranges. Specific parameters can be customized and adjusted by the professional technical team of Roltec according to the user’s boiler specifications and ventilation requirements, ensuring precise matching between the equipment and on-site working conditions to achieve optimal operating efficiency.

Brand Guarantee and Service Commitment

As a professional fan manufacturer integrating R&D, design, production, sales and services, Shandong Roltec Ventilation Equipment Co., Ltd. owns mature production lines and a professional technical R&D team. It focuses on the R&D and manufacturing of products such as centrifugal fans and axial fans, which are widely applied in multiple ventilation fields including metallurgy, power stations, chemical industry and mines. The company has gained market recognition by virtue of reliable quality and comprehensive services.

We provide all-round service guarantees for the G/Y4-73 boiler centrifugal blower:

Customized Services: We offer one-on-one model selection guidance and customized design based on customers’ boiler models, site conditions and ventilation demands to ensure precise product adaptation.

Quality Assurance: All products are manufactured in strict accordance with industry standards and go through multiple testing procedures before delivery to guarantee qualified quality and stable performance.

Installation Guidance: Professional on-site installation guidance is provided to assist customers with equipment installation and commissioning, enabling rapid put-into-service of the equipment.

After-sales Maintenance: A sound after-sales maintenance system is established to deliver regular inspections, fault repair, parts replacement and other services. We respond to customer needs in a timely manner, ensure long-term stable operation of equipment and eliminate customers’ worries.

Product Summary

Featuring core advantages of high efficiency and energy saving, sturdiness and durability, flexible adaptation as well as safety and reliability, the Roltec G/Y4-73 boiler centrifugal blower precisely meets the air supply and induced draft demands of various industrial boilers, balancing universality and customization. It can not only satisfy the high-efficiency ventilation and induced draft needs of large steam boilers in thermal power plants, but also adapt to special scenarios such as mine ventilation and chemical production, serving as an ideal supporting equipment for the efficient and safe operation of industrial boiler systems.

Backed by the technical strength and service guarantee of the Roltec brand, this product can effectively improve boiler combustion efficiency, reduce operating costs, cut down equipment failures and operation & maintenance workloads, create higher production value for users, and help enterprises achieve green, efficient and sustainable production.

FAQ

We sort out frequently asked questions about model selection, usage and maintenance with concise answers for quick reference:

Q: Can G4-73 and Y4-73 be used interchangeably?

A: No. The G4-73 delivers normal-temperature air (≤80℃) for air supply; the Y4-73 conveys high-temperature flue gas (≤250℃) with thickened volute plates and water cooling structure. Interchangeable use will cause equipment damage or energy waste.

Q: What key parameters are required for model selection?

A: Three core categories: boiler specification and application, air volume/total pressure requirements, and medium characteristics (temperature, dust content, etc.). Restrictions of special site conditions can be supplemented additionally.

Q: What are the key points and cycles of daily maintenance?

A: Key maintenance targets include impellers, bearings, lubrication systems and dampers. Check dust accumulation on impellers every 1 to 3 months, replace bearing lubricating oil every 6 months, conduct overall equipment inspection every half a year, and perform dynamic balance calibration annually.

Q: Is it mandatory to install a dust removal device for the Y4-73 induced draft fan?

A: Mandatory (dust removal efficiency ≥ 85%). Otherwise, dust will wear down components, cause impeller imbalance, and affect the operation of equipment and boilers.

Q: What is the after-sales response and maintenance process?

A: 24-hour response and 1-hour docking. Remote guidance for simple faults; on-site maintenance arrives within 24 hours in the province and 48 hours outside the province, with regular inspections after maintenance.

Q: Can the installation size or direction be customized?

A: Yes. The installation direction and shell structure can be adjusted, and dimensions can be optimized to adapt to on-site space and pipeline layout without affecting performance.

Scroll to Top