Product Overview
Model 9-19 and 9-26 high-pressure centrifugal fans are single-suction high-pressure ventilation equipment dedicated to industrial scenarios. They belong to the forward-curved blade high-pressure centrifugal fan series and serve as core ventilation and air supply equipment in industries such as industrial and mining, metallurgy, building materials, and chemical engineering.

Boasting the advantages of high wind pressure, strong suction force, stable operation, high efficiency and energy saving, the two fan models are widely applied in scenarios including high-pressure forced ventilation, material conveying, equipment induced draft and smoke exhaust, as well as process pressurized air supply. They can convey non-corrosive, non-self-igniting air and mixed gas free of viscous impurities for a long time, and are suitable for various high-intensity continuous operating conditions.
Among them, Model 9-19 fan focuses on ultra-high wind pressure output and adapts to high-pressure air supply and pressurization working conditions; Model 9-26 fan features a more balanced ratio of wind pressure to air volume, suitable for material conveying and negative pressure induced draft scenarios. The two models can meet the vast majority of industrial high-pressure ventilation demands.
Core Structural Composition
The 9-19 and 9-26 high-pressure ventilators feature a compact overall structure, mainly composed of five major parts: impeller, casing, air inlet, transmission assembly and support base. They boast a sturdy structure and convenient disassembly, assembly and maintenance:
- Impeller:The core working component. Model 9-19 is equipped with 12 forward-curved blades, while Model 9-26 has 16 forward-curved blades, both stamped and welded from high-strength steel plates. The impellers undergo strict static and dynamic balance calibration before delivery, with the maximum peripheral linear speed not exceeding 140m/s. They operate smoothly without jitter, feature high wear resistance and durability, and support 24-hour continuous operation.
- Casing:Integrally welded with high-quality steel plates, it has high structural rigidity and is not easy to deform, with excellent airtightness. No air leakage or pressure relief occurs under high-pressure operation, effectively ensuring wind pressure stability.
- Air Inlet: Adopting a convergent streamlined structure, it ensures smooth air intake and low wind resistance, effectively reducing air intake loss and improving the overall operating efficiency of the ventilator.
- Transmission and Base:Small sizes (4.0#-6.3#) adopt a support fixed structure, and large sizes (7.1#-16#) are equipped with a dedicated transmission unit. It supports multiple drive modes including A direct connection, C belt drive and D coupling drive, adapting to different installation spaces and power requirements.
Core Technical Parameters
- Unit specification: 4.0#~16#, impeller diameter 400mm~1600mm, covering working conditions of all sizes
- Air volume range: 800~130000m³/h
- Static pressure range: 3000~17000Pa with strong high-pressure output performance
- Working medium: air, non-corrosive, non-self-igniting and non-viscous industrial gas; dust content of medium ≤150mg/m³
- Working temperature: conventional -20℃~80℃, suitable for normal temperature industrial working conditions
- Driving modes: Type A direct connection, Type C belt drive, Type D coupling drive
- Core Advantages of the Product
- High Pressure & High Efficiency with Strong Working Condition Adaptability: Adopting a dedicated forward-curved blade design, it delivers stable and powerful wind pressure output with a wide efficient operating range and smooth performance curve. It maintains high operational efficiency under various working conditions and achieves remarkable energy-saving effects compared with traditional fans.
- Stable Operation and Lower Noise: The impeller undergoes precise balance calibration, resulting in low overall unit vibration and smooth operation. It features a low A-weighted sound level, effectively improving the workshop working environment and complying with industrial noise reduction standards.
- Sturdy and Durable with Long Endurance: The whole unit is made of high-strength materials; the impeller is wear-resistant and impact-resistant with an excellent sealing structure. It maintains no air leakage and no odor backflow under high-pressure operation, supports round-the-clock non-stop operation, and boasts low failure rate and long service life.
- Flexible Installation and Easy Maintenance: Multiple driving modes are optional with a modular structural design for easy disassembly and assembly. Daily cleaning and parts replacement require no complex procedures, greatly reducing operation and maintenance costs.
- Scope of Application
It is mainly used for high-pressure forced air supply of forging furnaces, boilers and industrial kilns. It is also suitable for pneumatic conveying of materials such as grain, plastics and dust particles. Additionally, it can be applied to scenarios including negative pressure induced draft of industrial equipment, waste gas exhaust, high-pressure ventilation in workshops, and pressurization of dust removal systems. It is widely used in industries such as metallurgy, building materials, chemical industry, grain processing, light industry and mining.

FAQ
Q1: What are the core differences between the 9-19 and 9-26 high-pressure ventilators, and how to select the right model?
A1: Model 9-19 is equipped with 12 blades, featuring extremely high wind pressure and moderate air volume, suitable for kiln pressurization and high-resistance ventilation working conditions. Model 9-26 has 16 blades, delivering large air volume with balanced wind pressure ratio, ideal for material conveying and negative pressure smoke exhaust scenarios. Model selection can be made according to on-site wind pressure and air volume requirements.
Q2: Can this high-pressure ventilator convey gas containing dust and particulate matter? Are there any usage restrictions?
A2: It can convey slightly dusty gas with dust content ≤150mg/m³. It is forbidden to convey corrosive, flammable, explosive and high-temperature viscous gas. Anti-corrosion and explosion-proof models can be customized for special working conditions.
Q3: What are the main causes of insufficient wind pressure and reduced suction during fan operation? How to solve the problems?
A3: Insufficient wind pressure is mostly caused by dust accumulation and blockage on the impeller/air inlet, belt slippage, air leakage in pipelines, and impeller wear and imbalance. Corresponding solutions: regular dust cleaning, tensioning or replacing belts, optimizing pipeline sealing, and inspecting or replacing the impeller.
Q4: Do the 9-19 and 9-26 high-pressure ventilators support 24-hour continuous operation? What is the daily maintenance cycle?
A4: The equipment supports 24-hour continuous industrial operation. Daily maintenance: daily inspection of noise, vibration and operating parameters; monthly dust cleaning and inspection of component tightness; quarterly lubrication refilling and belt wear inspection.
Q5: What causes excessive operating noise and severe body vibration of the fan, and how to deal with it?
A5: Main causes and solutions for heavy vibration and noise: Clean and calibrate the impeller if unbalanced due to dust accumulation; fasten loose bolts and replace aging shock absorption pads; replenish lubricant or replace worn bearings; adjust pipelines if pulled by pipeline stress.