In medium and small-sized coal-fired and biomass boiler systems, induced draft fans serve as critical equipment to maintain furnace negative pressure, smoothly discharge high-temperature flue gas and ensure stable boiler combustion. Exposed to erosion from high-temperature flue dust and solid particulate matter, conventional induced draft fans commonly suffer from rapid abrasion, high energy consumption and frequent malfunctions. Drawing on years of experience in fan R&D and manufacturing, Shandong Roltec has optimized and upgraded based on the traditional Y5-47 model to develop the Y5-48 series centrifugal boiler induced draft fan. Boasting comprehensive strengths including high efficiency and energy saving, excellent wear and high-temperature resistance, stable operation and easy maintenance, this product has become the mainstream matching equipment for flue gas extraction of industrial boilers with a capacity ranging from 1 ton to 20 tons per hour, and is widely adopted in high-temperature exhaust scenarios such as steam boilers, hot water boilers and waste heat drying kilns.

Y5-48 boiler fan (2)

I.Product Overview

The Y5-48 is a single-inlet medium-pressure boiler-specific induced draft fan covering the full model range from No4C to No12.5C. It features two structural configurations: type C belt drive and type D coupling drive, enabling flexible model selection based on on-site installation conditions. The fan impeller is available in left-hand and right-hand rotation directions, while the air outlet comes in three standard installation angles of 0°, 90° and 180°, matching the pipeline layouts of various boiler rooms. Under standard operating conditions, it can convey boiler flue gas at a temperature of ≤250℃. After qualified dust removal treatment, the dust content of flue gas is controlled below 150mg/m³. Apart from boiler exhaust gas extraction, this fan can also be applied to draw high-temperature waste gas from heat treatment kilns and small environmental dust removal equipment, boasting outstanding versatili

 

II.Core Product Advantages

1.Optimized pneumatic structure with remarkable energy conservation and consumption reduction

The Y5-48 fan is equipped with 12 pieces of low-alloy backward inclined flat blades and streamlined convergent air inlet featuring well-designed aerodynamics, enabling an overall operating efficiency of over 83% alongside a wide high-efficiency working range. The unit maintains superior operating efficiency even when the boiler undergoes fuel replacement or load fluctuation, cutting power consumption by approximately 15% compared with the conventional Y5-47 fan model. A petal-type manual air damper comes as standard for the fan inlet, allowing on-site fine-tuning of air volume and wind pressure by operators to precisely adapt to actual boiler loads. For refined energy-saving retrofits, variable-frequency motors can be optionally installed to further cut no-load power consumption via rotational speed regulation and slash corporate electricity expenses over long-term operation.

 

2.Robust material selection for outstanding high-temperature resistance and anti-abrasion against flue dust

Key components are constructed from wear-resistant materials to suit the harsh operating environment of high-temperature dust-laden boiler flue gas. Impellers are made of 16Mn wear-resistant alloy steel to withstand continuous erosion from high-temperature dust and short-term thermal shock; casings are fabricated via thickened steel plate welding, with dedicated ash-cleaning and maintenance ports pre-reserved for medium and large-size models. Small-sized models from No.4 to No.6.3 withstand a regular operating temperature of 200℃, while models of No.8 and above have a standard service temperature of 140℃. Water-cooled bearing housings and stainless steel impellers are available for customized production under special working conditions to achieve a maximum temperature resistance of 350℃. High-temperature specialized lubrication parts are adopted for bearings, and Type-C units are fitted with dustproof end caps to prevent flue dust from contaminating lubricant, minimizing the risk of bearing seizure from the source and significantly extending the overall service life of the equipment.

3.Precision dynamic balance calibration for round-the-clock stable operation

All impellers undergo both static balance and high-speed dynamic balance inspection before factory delivery with superior machining precision, resulting in overall unit vibration far below national standard limits. Featuring a smooth performance curve free of sharp peaks, the unit poses no overload risks during boiler startup/shutdown and load fluctuation, enabling non-stop continuous 24-hour operation. Type C belt drive delivers excellent shock absorption while Type D flexible coupling mitigates transmission impact, ensuring low operating noise. It meets the long-term continuous production requirements of boiler rooms and cuts economic losses caused by unscheduled boiler shutdowns.

 

4.Flexible & easy installation with low subsequent maintenance cost

Three air outlet angles combined with clockwise/counterclockwise rotation options are available for the fan, supporting renovation of new and existing boilers without extensive civil engineering modification of workshops. An ash cleaning access door is prefabricated on the casing, allowing ash removal from impellers directly after opening the door instead of dismantling the entire flue gas duct. Rotational speed of Type C models can be adjusted flexibly by replacing belt pulleys to modify operating parameters; Type D models feature low transmission loss and stable performance. High interchangeability of spare parts facilitates convenient market procurement and greatly reduces routine maintenance and component replacement expenses.

 

III. Multi-scenario Practical Applications

  1. Industrial boiler sector: Compatible with coal-fired, biomass and gas-fired steam/hot water boilers rated from 1 to 20 tons per hour for high-temperature flue gas extraction and stable furnace negative pressure maintenance;
  2. Waste heat processing industry:High-temperature waste gas extraction for small hazardous waste waste heat boilers, workpiece drying kilns and heat treatment furnaces;
  3. Environmental supporting projects: Negative-pressure exhaust at the downstream of dust removal equipment and high-temperature waste gas treatment for small and medium-sized chemical workshops.

 

IV.Reference Parameters of Common Models

Machine Numberrotational speed r/mintraffic m³/hTotal pressure PaSupporting motor  kW
4C35502932~55641501~22215.5
5C31505304~98511913~281911
8C180012415~230571823~268622
10C160019778~396742332~353155
12.5C140033800~678032794~4234110

V.Precautions for Use

To prevent rapid abrasion of the impeller caused by dust, a dust removal equipment with a dust collection efficiency of over 85% must be installed at the inlet of the Y5-48 induced draft fan to strictly control the dust concentration in flue gas, which serves as an essential prerequisite for the fan’s long-term stable operation.

 

VI.Frequently Asked Questions (FAQ) 

Q1: What tonnage of boilers is the Y5-48 compatible with, and what is the permissible flue gas temperature?

A1: It fits various industrial boilers ranging from 1 ton to 20 tons; the standard working medium temperature shall not exceed 250℃, the temperature for Model 4C-6C is no higher than 200℃, and conventional temperature for models above 8C is limited to 140℃.

 

Q2: Is it mandatory to equip a dust collector when installing the Y5-48 induced draft fan?

A2: A dust collector with dust removal efficiency ≥85% is compulsory to limit flue gas dust content below 150mg/m³ and prevent premature scrapping of the impeller due to severe abrasion.

 

Q3: How to adjust the air volume of the Y5-48 fan?

A3: A manual inlet damper comes as standard configuration; speed regulation for C-type models can be realized by replacing belt pulleys or installing a variable frequency drive system.

 

Q4: Can the air outlet angle and rotation direction of the fan be customized as required?

A4: Both left-hand and right-hand rotation directions are available, alongside three optional outlet angles of 0°, 90° and 180°, which can be specified during order placement.

 

Q5: What differentiates the Y5-48 from the legacy Y5-47 model?

A5: The Y5-48 is an upgraded version featuring larger air flow and wider high-efficiency operating range under the same model size, with superior energy-saving performance and wear resistance compared to the Y5-47.