The G/Y6-41 boiler centrifugal forced and induced draft fan is one of the most widely applied and stably performing special ventilation equipment supporting small and medium-sized industrial boilers at present. Featuring mature structural design, excellent working condition adaptability and remarkable advantages of energy conservation and durability, it serves as the standard matching fan for various coal-fired hot water and steam boilers, and is extensively applied in numerous industrial sectors including heating supply, textile, food, chemical engineering and building materials. This fan series consists of two models: the G6-41 boiler forced draft fan and the Y6-41 boiler induced draft fan. Matched as a set with separate respective functions, they perfectly satisfy the full set of working condition requirements for boiler combustion-supporting air supply and flue gas exhaust.

In terms of equipment functional configuration, the two fans feature clear division of labor and efficient coordination. The G6-41 forced draft fan is mainly responsible for delivering clean normal-temperature air to the boiler furnace, continuously supplementing oxygen required for combustion to achieve more sufficient coal combustion. It effectively improves the thermal efficiency of the boiler, reduces fuel waste and smoke emission, and ensures stable temperature rise and pressure-stable operation of the boiler. As the core equipment for boiler flue gas exhaust, the Y6-41 induced draft fan can withstand high-temperature boiler flue gas for long-term operation, stably extract flue gas inside the furnace and maintain balanced negative pressure in the furnace. It thoroughly resolves common faults such as poor boiler flue gas exhaust, flue gas backflow, ash accumulation in the furnace and slow temperature rise, thus guaranteeing the safe and orderly operation of the boiler system.
In terms of product performance design, the G/Y6-41 series fans are developed based on fluid dynamics simulation optimization. Equipped with streamlined air inlet structures and optimized arc-shaped impellers, they minimize ventilation resistance and boost the overall aerodynamic efficiency of the unit. Compared with conventional old-style boiler fans, they consume less energy and deliver more stable air volume and air pressure. The core impellers of the equipment are integrally welded from thickened steel plates, featuring solid workmanship and stable structures. Among them, the impellers of induced draft fans are enhanced with wear resistance to cope with the scouring of boiler dust, greatly improving their wear resistance and high-temperature resistance. Each complete unit undergoes high-precision dynamic balance calibration, which effectively avoids excessive vibration and loud noise during high-speed operation. The fans run smoothly and quietly, capable of meeting the demand for 24-hour non-stop continuous operation in industrial scenarios.
This series of fans boasts excellent installation adaptability and working condition compatibility. Featuring a compact overall structure and rational layout, they support two rotation directions: left-hand rotation and right-hand rotation. The air outlet can be adjusted to multiple angles, making the fans suitable for new and old boiler rooms, narrow installation spaces, and various non-standard installation scenarios. Multiple transmission modes are available, including direct connection, belt drive and coupling drive, which can be selected according to equipment tonnage and service requirements. The fans match small and medium-sized boilers ranging from 0.5 tons to 10 tons, and are compatible with various commonly used coal types such as bituminous coal and anthracite coal, offering outstanding versatility.
Furthermore, the equipment balances practicality and cost-effectiveness. Its modular split structure facilitates disassembly, assembly, inspection and maintenance. Wearing parts such as bearings and belts are highly universal, easy to source and low-cost to repair, substantially cutting enterprises’ later operation and maintenance expenses. Users can flexibly adjust air volume and air pressure via manual air dampers, or install frequency conversion devices to realize stepless speed regulation. This precisely adapts the equipment to boilers operating under high and low loads, further reducing energy consumption during operation and delivering remarkable economic benefits over long-term service.
Boasting numerous advantages including energy efficiency, high wear resistance, stable operation, wide adaptability and easy maintenance, the G/Y6-41 boiler centrifugal forced draft and induced draft fan thoroughly addresses the pain points of traditional boiler fans such as high power consumption, frequent damage, numerous malfunctions and excessive noise. It is a cost-effective optimal equipment for new supporting installations of industrial boilers and upgrading and replacing aging fans, and has won widespread recognition and trust from users across all industries thanks to its reliable quality.
The G/Y6-41 boiler centrifugal forced draft and induced draft fan is a special supporting fan for 0.5–10 ton industrial boilers, used as a complete set consisting of the G6-41 forced draft fan and the Y6-41 induced draft fan. It is currently the most commonly used and most cost-effective ventilation and smoke exhaust equipment for small and medium-sized boilers.
G6-41 Forced Draft Fan: It transports clean air at normal temperature to supply oxygen for boiler combustion, enabling more sufficient fuel combustion, improving boiler thermal efficiency, saving fuel and maintaining stable operating wind pressure.
Y6-41 Induced Draft Fan: It is specially designed to extract high-temperature flue gas from boilers with a temperature resistance up to 250°C. It stably maintains furnace negative pressure, resolves issues including poor smoke exhaust, flue gas backflow and slow boiler temperature rise, and adapts to industrial dust removal and smoke exhaust working conditions.
The fan adopts an optimized fluid structure with low wind resistance and excellent energy-saving performance, consuming less power compared with old-style fans. Its reinforced and wear-resistant impeller as well as high-precision dynamic balance of the whole unit deliver low vibration and noise, enabling 24-hour continuous operation with sturdy durability and low failure rate.
The equipment features flexible installation, supporting forward and reverse rotation as well as air outlets at multiple angles. A variety of transmission modes are optional, making it compatible with both new and old boiler rooms. With a modular structure, it is easy to disassemble, assemble and inspect, and its universal accessories reduce maintenance costs. It is widely applied to boilers in industries including heating, printing and dyeing, food processing, chemical engineering and building materials.
FAQ
Q1: Can the forced draft fan and induced draft fan be used separately?
A: No. The two fans are matched as a complete set and operate in coordination. Separate operation will unbalance air supply and flue gas exhaust, resulting in poor combustion, smoke emission and unstable operation.
Q2: Can the induced draft fan be installed without a dust remover?
A: It is not recommended. Flue gas with high dust content will rapidly wear the impeller, causing excessive vibration, frequent malfunctions and a sharp reduction in service life.
Q3: What size boilers are they compatible with? Can they be retrofitted as replacements?
A: They fit 0.5–10 ton boilers. Flexible adjustment of installation parameters is supported, and major pipeline modifications are unnecessary, making them ideal for retrofitting and replacing old fans.
Q4: How to solve insufficient air volume and air pressure?
A: Check for air leakage and blockages in pipelines as well as loose belts. Regularly clean dust accumulated on the impeller. Variable frequency speed regulation can be equipped to stabilize air volume and reduce energy consumption.
Q5: What is the temperature resistance of the induced draft fan? Is continuous operation allowed?
A: The standard temperature resistance is ≤250℃. Stable 24-hour continuous operation is permitted under compliant working conditions. Over-temperature operation is prohibited to prevent equipment aging and damage.