C5-51 Series Centrifugal Fans for Dust Removal
The transmission fan is air, and the induced draft fan is flue gas or gas containing impurity particles. When the impurity concentration is less than 200 mg/m3 you will have a longer life more than 4years. If it contains large impurities, it can also be used, but the service life will be shortened. The operating temperature of the induced draft fan shall not exceed 250℃.
The impeller is rear-tilt wing oblique cut blades welded between the arc conical front plate and the flat rear disc. Due to the use of wing blade, the fan ensures high efficiency, low noise and high strength. The impeller passes through static and dynamic balance correction, so the operation is stable. The impeller structure of the open and induced draft fans of the same machine number is the same.
- Technical Data Sheet
| No. | Rotation | Flow | air pressure | Internal power |
| № | r/min | m3/h | Pa | kW |
| 8 | 1450 | 9882-23091 | 1011-2011 | 7.08-12.7 |
| 10 | 1450 | 19300-45100 | 2297-3142 | 24-38.9 |
| 12 | 1450 | 33350-77933 | 3307-4525 | 59-128 |
| 14 | 1450 | 52959-123754 | 4501-6416 | 129-209 |
| 16 | 1450 | 79053-184730 | 4043-8044 | 252-408 |
| 18 | 960 | 74521-174139 | 3262-4649 | 132-213 |
| 20 | 960 | 102223-238874 | 4027-5740 | 223-361 |
| 22 | 960 | 136059-317942 | 4872-6945 | 360-582 |
| 25 | 730 | 151821-354774 | 3638-5186 | 300-485 |
| 28 | 730 | 213298-498431 | 4564-6505 | 528-854 |
| 29.5 | 730 | 249447-582905 | 5066-7221 | 685-1108 |
C5-51 Series Low-Pressure Centrifugal Fans for Application
5-51 series of products are widely used in power plants, large environmental dust removal and desulfurization and denitration system, smelting industry environmental protection dust removal fields, and also can be used in 2-670 t/h steam boiler fan systems (design temperature is 80 ℃) in thermal power plant for centrifugal fan and blower fan for boiler.